The Pro Headspa Journal
Practical guides18 min read

Ultra LED Sauna Dome: User Guide and Videos

Installation, connections, controls and session monitoring: the illustrated guide for the Dôme Sauna Ultra and Ultra LED, with eight French videos and a 28-page PDF.

Dôme Sauna Ultra LED : tutoriel d’utilisation et vidéos

1. Getting Started

Start with safety and connections. Then move on to the control box, followed by client preparation and monitoring. The videos complement the steps explained in this guide.

Diagram of the three zones: large UPPER dome, small LOWER dome, and MAT mat; head outsideEnlarge the illustration
Reference points from the manual: UPPER for the upper body, LOWER for the legs, MAT for the mat.

Video 01 · Introduction · 2:34

The assessment and restrictions to check before any session

Situations excluded by the manual

Pregnancy, fever, uncontrolled heart condition, implanted pacemaker or defibrillator, open wounds or recent burns, being under the influence of alcohol or drugs: do not conduct the session.

Situations requiring prior medical advice

The manual requires written medical advice, in particular in cases of significant blood pressure disorders, insulin-dependent diabetes, epilepsy, multiple sclerosis, circulatory problems, cancer or ongoing treatment, recent surgery, eczema or psoriasis flare-ups, and certain medications. Consult the full list in Chapter 06.

A separate rule for PEMF

Do not activate this function in the presence of an active electronic implant, a metal implant in the exposed area, pregnancy, epilepsy, or a known neurological disorder. If in doubt, leave it deactivated and seek advice from the relevant healthcare professional.

2. Installation and Connection

Layout plan: support of at least 180 × 80 cm, 50 cm clear on each side, head and outlet unobstructedEnlarge the illustration
Place the control box in a dry place, within reach of the practitioner, without blocking the outlet.
  1. Check the support

    Flat, dry, and stable surface. The manual requires a table at least 80 cm wide and 1.80 m long, suitable for the weight of the client and the entire unit.

  2. Unroll the mat

    Stones facing up, flat, without creases. Place a clean cloth between the stones and the client's skin.

  3. Position the two shells

    Large dome on the upper body side, small dome on the leg side. Check the casters and the safety margin from the edges.

  4. Clear the access areas

    Leave at least 50 cm on each side according to the manual. Keep the head and outlet clear. The client must be able to push the domes away with one hand.

  5. Place the control box

    Within reach of the practitioner, in a dry place, uncovered. The cables must not be stretched, pinched, or placed in a walkway.

Locate the ports on the back of the control box

Annotated photo of the ports: 1 mat, 2 small dome, 3 large dome, 4 I/O switch, 5 mains powerEnlarge the illustration
The same numbers are used in the diagram and in the following steps.

Connect the control box with the unit unplugged

Wiring diagram: mat to port 1, small LOWER dome to 2, large UPPER dome to 3, switch 4 and mains power to 5Enlarge the illustration
The mains power is always connected last. Reference points 1 to 5 correspond to the photo above.
  1. Cut the power

    Rear switch 4 to O, mains cable unplugged from the wall outlet.

  2. Connect the mat

    Plug the white cable into port 1, labeled "Mat connector". Align the key, insert without forcing, and screw on the ring.

  3. Connect the two domes

    Small dome to black port 2: LOWER, leg side. Large dome to black port 3: UPPER, upper body side. On the dome side, insert the metal connector at the base of each shell until it locks.

  4. Connect the mains power last

    Check that no cable is pinched. Insert the cord into base 5, then plug it into a grounded wall outlet.

  5. Turn on the power

    Flip switch 4 to I. POWER then controls the operation and standby of the control box; it is not the main switch.

See the connectors and their locking
The three connection steps: align the key, insert without forcing, then lockEnlarge the illustration
Annotated photo of the dome connector: 1 latch, 2 metal body, 3 cableEnlarge the illustration
Release the latch, then pull on the body of the connector; never on the cable.

Control box side

Turn the connector gently until its key is aligned. Insert it fully without effort and tighten its ring. Do not bend the pins.

Dome side

Align the notches, insert the metal connector until it locks. To remove it, release the latch then pull on the body of the connector, never on the cable.

If UPPER and LOWER are reversed

During an empty test, check which shell heats up. If UPPER controls the small dome, cut the power, unplug the mains power, and reverse the two black connections. Do not handle the ports while they are energized.

3. Understanding the Control Box

Annotated control box: 1 TIME, 2 UPPER, 3 LOWER, 4 MAT, 5 arrows, 6 POWER, 7 START, 8 LIGHT, 9 PEMFEnlarge the illustration
Reference points 1 to 9 correspond to the explanations below. The video shows the same logic on the black control box.

1 · TIME

Cycle duration and remaining time, in minutes.

2 · UPPER

Temperature of the large dome, upper body side.

3 · LOWER

Temperature of the small dome, leg side.

4 · MAT

Temperature of the mat; frequency in hertz when PEMF is active.

5 · Arrows ▲ / ▼

Under each display: increase or decrease its value. Read the displayed mode and value first.

6 · POWER

Turn the control box on or put it in standby.

7 · START

Start the cycle; a second press interrupts it.

8 · LIGHT

On the LED version, control the light independently of the heating.

9 · PEMF

Activate or deactivate this mat function. The frequency is displayed on MAT with the Hz indicator.

Video 03 · Using the Control Panel · 1:39

Before the first client: the empty test

Follow Chapter 07 of the manual: three zones at 50 °C for 30 minutes, then control at 70 °C for 10 minutes, without anyone in the device. Check the UPPER/LOWER correspondence and the absence of overheating or anomalies.

Start the cycle in the correct order

Rear switch to I, POWER, TIME, UPPER, LOWER, MAT. Check the four values. Activate LIGHT if your version allows it; choose PEMF only after checking the restrictions. Press START.

Display technical ranges and manual reference points

TIME: 5 to 90 min

Technical range. The manual recommends 45 min for regular use, without exceeding 60 min; the session can and should be shorter depending on tolerance.

UPPER / LOWER: 25 to 90 °C

Technical range of the shells. The manual gives 55 to 65 °C as a common reference, to be adapted; 90 °C is not a routine instruction.

MAT: 25 to 80 °C

Technical range of the mat. The common reference of the manual is 45 to 55 °C. Check that it is indeed in temperature mode.

First session

The manual suggests starting low, around 50 °C for 20 to 30 min. Reduce if necessary; do not try to achieve heavy sweating.

Adapt without automation

An increase after three or five sessions is never mandatory. Comfort, the assessment, tolerance during the previous session, and the restrictions of the manual take precedence over the session number.

Record what was actually done

Note separately the two dome temperatures, the mat temperature, the duration, and, if applicable, the PEMF frequency. Also record any reduction or interruption.

MAT: temperature or frequency?

The same display is used for two pieces of information. In temperature mode, it concerns the mat heating. After activating PEMF, it displays the frequency of this function in hertz.

MAT toggle diagram: temperature in degrees Celsius or PEMF frequency from 1 to 30 HzEnlarge the illustration
Locate the Hz indicator before changing MAT. A new press on PEMF returns to temperature.
  1. Check the restrictions

    This option is not necessary to start a heat session. Without certainty about the client's compatibility, leave it deactivated.

  2. Activate the desired mode

    Press PEMF. Observe the change of MAT and the frequency indicator. Use the arrows under MAT to change the frequency.

  3. Stay within the actual range

    The control box and the manual indicate 1 to 30 Hz. A value of 0.5 Hz mentioned orally is not available on this setting.

  4. Return to temperature

    A new press on PEMF deactivates this function and restores the temperature display. Check the mode before starting and record it in the log.

4. Prepare and accompany the client

The videos distinguish between a profile accustomed to effort and a more sensitive profile. Use this distinction as a starting point for a conversation, never as an automatic authorization.

What to ask

Is this the first session? How does the person usually tolerate heat? Are they tired or dehydrated? Do they present an element of the safety assessment? What comfort are they looking for today?

What to explain

The head remains outside. The client can push the shells away to clear themselves and must report any discomfort immediately. The practitioner remains in the room during the entire session.

What to prepare

Remove jewelry, watches, and other items specified in the instructions; place clean linen on the mat; ensure water is available; and clear the exit. Check with the client that they can get out before starting.

Video 04 · Introduction to Treatments · 0:55

  1. Before START

    Reread the displayed instructions; check the linen, head position, access to the control box, and free movement of the domes.

  2. At startup

    Ask the client to describe the heat they feel. Check that they can communicate without effort and that no support is uncomfortable.

  3. During the cycle

    Never leave the room. The instructions require checks at least every 10 minutes; respond immediately to any discomfort, without waiting for the next check.

  4. In case of discomfort

    Stop with START and open the shells. Dizziness, nausea, palpitations, chest tightness, headaches, or chills require stopping. A serious situation requires appropriate emergency services.

  5. At the end

    Open the domes. The instructions require at least 2 minutes lying down, then a gradual sitting and standing up with assistance, after checking for dizziness.

  6. Before leaving

    Allow time for rest, offer water according to the client's needs and specific instructions, then record the settings and their experience in the logbook.

5. Understanding the Functions

Interior of the LED Ultra Sauna Dome: stones, mat, and red light bands
Heat, red light, near-infrared, and PEMF: distinct functions.

Far Infrared

Thermal emission: the instructions indicate 5 to 15 micrometers (µm). It relates to the heat of the zones, not a visible color.

Red Light

660 nanometers (nm), on the LED version. It is controlled with LIGHT.

Near-Infrared

850 nm, on the LED version. Invisible to the naked eye; the absence of red on an emitter is not enough to conclude that it is off.

PEMF

Mat function, distinct from the LEDs and heating. Its frequency is measured in Hz, not nm.

Video 02 · Technology · 4:28

Combining the Dome with another treatment
Example of a combined Head Spa and Sauna Dome treatment, head outside the shellsEnlarge the illustration
A compatible table does not make the Dome waterproof: the control box and connections must remain protected from water.

Simultaneously

On a compatible support, the head remains outside the shells. The practitioner maintains immediate access to the control box, the client, and the domes. No accessory or linen blocks the movement.

With a head spa

Strictly separate the wet area from the device: the control box, outlets, and connections must remain dry, protected from splashes. The compatibility of the support does not make the Dome waterproof.

Sequentially

Allow for a gradual exit and rest before the next treatment. Reassess comfort; do not combine durations or demands as if it were a single treatment.

What to avoid

A second treatment that requires leaving the room, masks discomfort, or prevents the client from getting out. The combination must not be used to promise enhanced medical efficacy.

6. The Four Treatment Videos

These videos explain the logic of progression and adaptation to the client's experience. Their titles are used to find the content: they do not constitute a promise of slimming results, nor a detoxification or treatment protocol.

Building a comfortable progression.

The video titled "The Slimming Treatment" illustrates a progression over several sessions. The key point to remember is adjusting based on the client's feedback, without promising weight loss.

Video 05 · 1. The Slimming Treatment · 4:01

Key points and precautions

At the first appointment

Review the client's history, explain the exit, and choose a short session with moderate heat according to the instructions. Observe their experience, not the amount of sweat.

At the next appointment

Reread the logbook: heat felt, any discomfort, interruptions, rest after the session. Keep the same settings if comfort was good; no increase is required.

If you change a setting

Proceed carefully and avoid increasing both duration and heat significantly at the same time. Do not apply the Dome's temperatures to the mat; the limits are different.

How to present it

Talk about a tailored heat and wellness experience. Sweating does not allow you to promise a reduction in body fat or results after five or eight sessions.

Prioritize gentleness, without a goal of sweating.

The "Detox Treatment" video offers a gentler and more gradual heat approach. In practice, focus primarily on the welcome, tolerance, and follow-up.

Video 06 · 2. The Detox Treatment · 1:30

Key points and precautions

Your operational goal

A comfortable session, which can be shortened. The person must be able to describe what they feel and leave the setup easily.

What to monitor

Excessive heat, marked thirst, fatigue, or discomfort are not results to be sought. Reduce or stop depending on the situation.

What to record

UPPER, LOWER, and MAT values, actual duration, and experience. Do not judge success by weight lost immediately after the session.

The right words

Present the treatment as a moment of heat and relaxation. Do not claim the elimination of mercury, lead, cadmium, or other heavy metals through this treatment.

After the activity, check the person's condition.

The "Sports Recovery Treatment" video is intended for active people. A habit of exercise does not justify seeking extreme temperatures.

Video 07 · 3. The Sports Recovery Treatment · 2:37

Key points and precautions

Before setting up an athlete

Check their history, general condition, and heat tolerance. A person who is already very overheated, dehydrated, or unwell should not automatically receive additional heat as a solution.

Do not use extreme values

The 80 to 90 °C mentioned in the video are not used here as a client protocol. Use the cautious guidelines in the instructions, adapt the session, and maintain continuous monitoring.

PEMF remains optional

The statement that there are no contraindications to this function should not be followed. Restrictions regarding implants, pregnancy, and other situations are found in chapter 06 of the instructions.

Your conversation with the client

Offer a moment of relaxation. Do not present the Dome as a replacement for cardio exercise, nor as a guaranteed way to eliminate lactic acid or speed up recovery.

A calm setting. Well-tolerated heat.

The "Anti-Stress Treatment" video focuses on the environment and relaxation. The practice remains centered on the comfort and safety of the session.

Video 08 · 4. The Anti-Stress Treatment · 1:28

Key points and precautions

Prepare the atmosphere

Explain the process and agree on a simple way to call you. Calmness must not prevent you from hearing the client or monitoring their condition.

Leave the choice to the client

A shorter or less hot session may be preferable. Do not automatically extend it because the person seems relaxed.

If you use PEMF

First check the restrictions. The device range starts at 1 Hz; do not try to set it to 0.5 Hz. Check the MAT mode and record the chosen frequency.

At the end

Collect their experience without promising to treat insomnia or an anxiety disorder. A wellness goal does not turn the PEMF function into a sleep treatment.

7. Maintenance and Troubleshooting

After each client

Stop the cycle, set the rear switch to O, and unplug. Allow it to cool, remove the linen, then wipe with a slightly damp microfiber cloth using water and black soap, as indicated in your instructions. No liquid should be poured directly onto the device.

Before putting it back into service

Dry with a soft cloth and replace with clean linen. Leave the shells open to ventilate. No liquid should remain near the connectors.

Once a month

The instructions call for a little baby body milk on the faux leather to preserve its suppleness.

What to avoid

Thinner, acetone, methylated spirits, white spirit, pure bleach, abrasives, and scouring sponges. The stones require no maintenance: do not move or remove them.

Regular checks

Inspect the cables, pins, casters, and coverings. In case of deterioration or abnormal behavior, contact customer service before continuing. No user-performed internal repairs.

See checks in case of an anomaly

Nothing turns on

Check that the rear switch is on I, the power cord is properly engaged, the wall outlet, and POWER.

One zone does not heat up

Check START and a suitable instruction. With the power off and the mains unplugged, check the connector for that zone.

UPPER controls the small dome

Reversed dome connections. With the power off and the mains unplugged, correct the two black plugs.

MAT seems to display a strange value

Check if PEMF is active: it may be a frequency, not a temperature.

Some diodes do not appear red

Check LIGHT and the LED version. Near-infrared is not visible to the naked eye; contact customer service if in doubt.

The cycle stopped

Check TIME and ventilation conditions. Do not repeatedly restart a device that has an anomaly.

Smoke, burning smell, hot cord, unstable display

Stop, unplug, do not use the device again, and contact customer service. Do not open it yourself.

8. Frequently Asked Questions and Downloadable Guide

Should I watch the eight videos before each session?

No. Watch the complete course for initial orientation. Then, use the table of contents, the memo, and the chapters for the setting in question. The assessment and pre-session checks remain necessary for each use.

Is the maximum of 90 minutes a recommended duration?

No. It is a technical limit of the timer. The November 2026 user manual recommends a standard duration of 45 minutes, not exceeding 60 minutes, and a shorter first session. Individual tolerance may require less.

Should I increase the temperatures for each appointment?

No. There is no automatic increase linked to the session number. Re-read the log, ask how the client feels, and respect the assessment, the user manual, and the limits specific to each area.

Is PEMF mandatory?

No. It remains optional and has specific restrictions. Check the contraindications before activating it; if in doubt, leave it deactivated.

Why does MAT display a frequency?

The display is shared. When PEMF is active, MAT shows the frequency in Hz; after deactivation, it returns to the mat temperature. Always check the mode before changing a value.

Can I leave the client alone when the cycle is running?

No. The practitioner must remain in the room during the entire session, with immediate access to the client, the shells, and START.

Why do some diodes appear to be off?

Red light at 660 nm is visible; near-infrared at 850 nm is not. Visual appearance is not enough to diagnose a failure. Check LIGHT and contact customer service if necessary.

Can I promise weight loss or detoxification?

No. The video titles identify training content; they do not constitute evidence of effectiveness. The user manual presents the device as a wellness device and excludes therapeutic, slimming, or detox claims.

The complete guide, also available in print

28 illustrated pages: installation, connections, controls, step-by-step session, eight video links with QR codes, pre-session memo, and printable log. French PDF, approximately 14.5 MB.

View the Dôme Sauna Ultra LED product page · Contact the Pro Headspa team

Sources and version of the guide

Pro Headspa orientation guide, Dôme Sauna Ultra and Ultra LED, 28 pages, layout dated November 3, 2026; user manual PH-NOT-DSU-2026-FR-V2, November 2026; French playlist "Dôme Sauna Ultra Prestige". Guide prepared for Pro Headspa validation before client distribution.

For the limits of "detox" claims and heat risks: NCCIH / NIH and CDC / NIOSH.